DeepManthan AI
Chiller Plant Intelligence
HVAC Chiller Plant Workflow Visualization
Interactive, animated simulations that explain how a chilled-water plant really works — from the core concepts and energy flow to live efficiency, multi-chiller staging, plant-health monitoring, and AI-driven optimization.
🖥️ Desktop viewing only. For the best experience, please open this suite on a laptop or desktop. The interactive simulators are not optimized for mobile screens.
📘
Start here — Concepts & Terminology
Plain-language reference for TR, kW, kW/TR, COP, ΔT, control levers and where the energy goes — with a heat-balance diagram and a live efficiency calculator. The best place to begin.
Open Reference →
Interactive Simulators
Watch the plant work, then drive it yourself.
💧
How a Chiller Works
Animated block diagram of every component — evaporator, compressor, condenser, pumps, cooling tower and AHU — with water and refrigerant flowing through all three loops.
View Animation →
🏭
Multi-Chiller Staging
Live simulator of three parallel chillers. Change the load and watch staging switch machines on and off, with a staged-vs-all-on efficiency comparison.
Launch Simulator →
Closed-Loop Escalation
A self-controlling plant that fights back. Trigger a load or weather spike and watch the escalation ladder — pump → chiller → tower → staging — with reactive vs predictive control.
Run the Plant →
💬
HVAC Operations Assistant
Ask the plant questions in plain English. 80+ operator queries — chillers, pumps, towers, energy and AI reasoning — each answered against one live plant scenario. Filterable and click-to-expand.
Open Assistant →
Plant Health Monitoring
Spot the symptoms of a plant whose health is slipping.
🌡️
ΔT Health Monitor
The flagship plant-health symptom. Induce coil fouling or over-pumping and watch chilled-water ΔT slide from healthy into fault, with a live trend.
Open Monitor →
🌦️
Two Triggers: Load + Weather
Load side (ΔT) and weather side (kW/ton) shown together — see how each trigger degrades a different signal, and why a hot day isn't a fault.
Open Dashboard →
Energy & Billing
Where the plant meets the electricity board.
🔌
Chiller Plant & the Electricity Board
A real MSEDCL mall bill decoded — contract demand, kVAh, power factor, TOD, and open access — showing how every chiller-plant decision lands on a ₹1.33-crore monthly invoice.
Open Breakdown →
💡 Font Size Adjustment
🍎 Mac Users Command + / −
🪟 Windows Users Ctrl + / −
🐧 Linux Users Ctrl + / −

Use these keyboard shortcuts to zoom in and out of the simulators for comfortable viewing.